Re: Help required regarding Borewell issue
Thanks tvsh, will lower the pump by another 20-30 feet and get back to with the result.
- June 20th, 2017, 7:57 pm
- Forum: Civil Construction
- Topic: Help required regarding Borewell issue
- Replies: 16
- Views: 20433
Re: Help required regarding Borewell issue
3000 Liters of water was a guess. ok to clarify while I was purchasing the vendor told me the pump belongs to Texmo not sister company Taro and to check on your point today I called vendor he said regarding the Starter board which controls the power supply as per the load. I have purchased L&T GU 10 ...
- June 20th, 2017, 3:02 am
- Forum: Civil Construction
- Topic: Help required regarding Borewell issue
- Replies: 16
- Views: 20433
Re: Help required regarding Borewell issue
Further lowering the Pump level will not help you in anyway and the yield is low.
Same way decreasing the pipe dia/pump capacity is also of now use, as you are able
to draw only the available water. Same qty you may extract at longer time.
The only option left out is to make use of the Rainwater ...
Same way decreasing the pipe dia/pump capacity is also of now use, as you are able
to draw only the available water. Same qty you may extract at longer time.
The only option left out is to make use of the Rainwater ...
- June 20th, 2017, 2:56 am
- Forum: Civil Construction
- Topic: Help required regarding Borewell issue
- Replies: 16
- Views: 20433
Re: Help required regarding Borewell issue
Hi tvsh, sorry exactly it is at 14 AMP and reduces to 10 AMP and 8.9 KW for initial 45 mins and 5.5 KW after 45 mins. I am not sure about the rating of the motor what you are looking however specification is 7.5 HP, 75 stage, 1305 head Range, Three phase. After pulling out the water in full force ...
- June 17th, 2017, 10:40 pm
- Forum: Civil Construction
- Topic: Help required regarding Borewell issue
- Replies: 16
- Views: 20433
Re: Help required regarding Borewell issue
Thanks tvsh. I will implement all your suggestion.. my query about changing mouth(tap) of the outflow from 1" inch to 0.5" inch will it effect the pump life? Will it damage my HDPE pipe? Any inputs or suggestions....
- June 17th, 2017, 1:24 am
- Forum: Civil Construction
- Topic: Help required regarding Borewell issue
- Replies: 16
- Views: 20433
Suggestion required on Below Borewell issue Question
Hi,
My Name is Harish. Recently I have drilled a borewell for residential use up to 1271 Feet. After drilling the borewell we left for 30 days and did camera scanning to check for water sources. We found one water source at 150 Feet (Water was flowing) and one empty source at 300 Feet (No Water ...
My Name is Harish. Recently I have drilled a borewell for residential use up to 1271 Feet. After drilling the borewell we left for 30 days and did camera scanning to check for water sources. We found one water source at 150 Feet (Water was flowing) and one empty source at 300 Feet (No Water ...